Top Essay Writers
Our top essay writers are handpicked for their degree qualification, talent and freelance know-how. Each one brings deep expertise in their chosen subjects and a solid track record in academic writing.
Simply fill out the order form with your paper’s instructions in a few easy steps. This quick process ensures you’ll be matched with an expert writer who
Can meet your papers' specific grading rubric needs. Find the best write my essay assistance for your assignments- Affordable, plagiarism-free, and on time!
Posted: July 2nd, 2022
ABSTRACT
This main purpose of this thesis is to investigate the principles connected to the construction of a passive house and to determine the viability of the passive house concept in Ireland.
We get a lot of “Can you do MLA or APA?”—and yes, we can! Our writers ace every style—APA, MLA, Turabian, you name it. Tell us your preference, and we’ll format it flawlessly.
Passive house is the result of the further development of the low energy house, it’s a performance based energy standard for building. Passive Houses use on average 90% less energy for space conditioning than code-designed houses.
Over the past decade there has been an increasing effort to reduce the amounts of carbon dioxide. With homes being one of the biggest contributors of carbon dioxide and with recent (EIA) Energy Information Administration survey showing that since 1950 there has been an increase in carbon dioxide emissions associated with residential homes.
It is therefore no surprise that there is a greater interest today in how homes preform in regards to energy consumption.
As part of an ongoing program to improve the quality of Irish housing, as well as decreasing
Totally! They’re a legit resource for sample papers to guide your work. Use them to learn structure, boost skills, and ace your grades—ethical and within the rules.
Ireland’s energy demand and carbon emissions as part of Irelands Kyoto protocol target, the Irish building regulations have gone through a lot of change in recent years. It is the current
government’s intention that by 2020 legislation will have brought Ireland to the point where
all new housing is zero-carbon low energy housing
Starts at $10/page for undergrad, up to $21 for pro-level. Deadlines (3 hours to 14 days) and add-ons like VIP support adjust the cost. Discounts kick in at $500+—save more with big orders!
The purpose of this thesis research is firstly to provide a detail understanding of the main concepts of passive housing by highlighting the fundamental requirements connected with low energy design and construction. Secondly to provide an understanding of the viability of passive housing and relevance of passive housing standards in Ireland today.
By means of critically accessing literature and through primary research by the means of an online questionnaire, the theme of this thesis is considered throughout this report.
Drawings and charts obtained from this research, as well as the benefits and problems associated with passive houses will be discussed and outlined.
TABLE OF CONTENTS
100%! We encrypt everything—your details stay secret. Papers are custom, original, and yours alone, so no one will ever know you used us.
Nope—all human, all the time. Our writers are pros with real degrees, crafting unique papers with expertise AI can’t replicate, checked for originality.
Our writers are degree-holding pros who tackle any topic with skill. We ensure quality with top tools and offer revisions—perfect papers, even under pressure.
Experts with degrees—many rocking Master’s or higher—who’ve crushed our rigorous tests in their fields and academic writing. They’re student-savvy pros, ready to nail your essay with precision, blending teamwork with you to match your vision perfectly. Whether it’s a tricky topic or a tight deadline, they’ve got the skills to make it shine.
1.5.2 Chapter 2: Literature Review
1.5.3 Chapter 3: Research Design and Methodology
Guaranteed—100%! We write every piece from scratch—no AI, no copying—just fresh, well-researched work with proper citations, crafted by real experts. You can grab a plagiarism report to see it’s 95%+ original, giving you total peace of mind it’s one-of-a-kind and ready to impress.
1.5.5 Chapter 5: Data analysis
1.5.6 Chapter 6: Research Findings
1.5.7 Chapter 7: Conclusions and recommendations
Yep—APA, Chicago, Harvard, MLA, Turabian, you name it! Our writers customize every detail to fit your assignment’s needs, ensuring it meets academic standards down to the last footnote or bibliography entry. They’re pros at making your paper look sharp and compliant, no matter the style guide.
For sure—you’re not locked in! Chat with your writer anytime through our handy system to update instructions, tweak the focus, or toss in new specifics, and they’ll adjust on the fly, even if they’re mid-draft. It’s all about keeping your paper exactly how you want it, hassle-free.
2.3.2 Passive House In Ireland
2.4 Passive House Certification
It’s a breeze—submit your order online with a few clicks, then track progress with drafts as your writer brings it to life. Once it’s ready, download it from your account, review it, and release payment only when you’re totally satisfied—easy, affordable help whenever you need it. Plus, you can reach out to support 24/7 if you’ve got questions along the way!
2.6 Passive House “Construction Techniques”
Need it fast? We can whip up a top-quality paper in 24 hours—fully researched and polished, no corners cut. Just pick your deadline when you order, and we’ll hustle to make it happen, even for those nail-biting, last-minute turnarounds you didn’t see coming.
Absolutely—bring it on! Our writers, many with advanced degrees like Master’s or PhDs, thrive on challenges and dive deep into any subject, from obscure history to cutting-edge science. They’ll craft a standout paper with thorough research and clear writing, tailored to wow your professor.
2.9 Barries To Development Of PH In Ireland
2. 10 Irish Building Regulations 2011: Part L
CHAPTER 3. RESEARCH METHODOLOGY
We follow your rubric to a T—structure, evidence, tone. Editors refine it, ensuring it’s polished and ready to impress your prof.
Send us your draft and goals—our editors enhance clarity, fix errors, and keep your style. You’ll get a pro-level paper fast.
3.4.1 Approaches To Data Collection
3.4.2 Data Colletion – Case Study
Yep! We’ll suggest ideas tailored to your field—engaging and manageable. Pick one, and we’ll build it into a killer paper.
3.4.3 Data Collection Questionnaire
3.4.4 Target / Selected Sample
Yes! Need a quick fix? Our editors can polish your paper in hours—perfect for tight deadlines and top grades.
CHAPTER 5. DATA ANALYSIS FOR QUESTIONNAIRE
Sure! We’ll sketch an outline for your approval first, ensuring the paper’s direction is spot-on before we write.
6.4 Developmen Of Passive House In Ireland
CHAPTER 7. CONCLUSION AND RECOMMENDATIONS
Definitely! Our writers can include data analysis or visuals—charts, graphs—making your paper sharp and evidence-rich.
7.2 Research Aims And Objectives
Appendix A – Online Questionnaire
We’ve got it—each section delivered on time, cohesive and high-quality. We’ll manage the whole journey for you.
Appendix B – Qualitative Questionnaire Questions
Yes! UK, US, or Aussie standards—we’ll tailor your paper to fit your school’s norms perfectly.
Figure 1: The Research Ship “Fram” was a Passive House (PASSIPEDIA, 1998)
Figure 2: “Out of the blue” – Irelands first certified PH (ARCHITECTURE, 2007)
Figure 4: Application of various types of insulation (Ebbs, 2012)
If your assignment needs a writer with some niche know-how, we call it complex. For these, we tap into our pool of narrow-field specialists, who charge a bit more than our standard writers. That means we might add up to 20% to your original order price. Subjects like finance, architecture, engineering, IT, chemistry, physics, and a few others fall into this bucket—you’ll see a little note about it under the discipline field when you’re filling out the form. If you pick “Other” as your discipline, our support team will take a look too. If they think it’s tricky, that same 20% bump might apply. We’ll keep you in the loop either way!
Figure 6: Typical Heat Recovery Ventilation System
Figure 7: Heat losses related to the airtightness level n50 (Saint Gobin)
Our writers come from all corners of the globe, and we’re picky about who we bring on board. They’ve passed tough tests in English and their subject areas, and we’ve checked their IDs to confirm they’ve got a master’s or PhD. Plus, we run training sessions on formatting and academic writing to keep their skills sharp. You’ll get to chat with your writer through a handy messenger on your personal order page. We’ll shoot you an email when new messages pop up, but it’s a good idea to swing by your page now and then so you don’t miss anything important from them.
Figure 10: Window Certified by Passive House Institute (2006)
Figure 11: Solar Power Per Capita & Wind Power Per Capita Leaders (Shahan, 2015)
Figure 12: Schematic of Solar Water Heating System (REUK.co.uk, 2017)
Figure 13: Annual end-use energy consumption
Figure 14: Specific Energy Consumption (Jennings, 2005)
Figure 15: Comparison of yearly energy consumption rate. (Ebbs, 2012)
Figure 16: Calculated Energy and CO2 emissions for 100m2 Irish dwelling
Figure 17: Various stages in composition of dissertation
Figure 18: Pragmatic approach to research. (Creswell, 2003)
Figure 20: ‘Out of the Blue’ First Floor (Antonelli, 2014)
Figure 21: ‘Out of the Blue’ Ground Floor (MosArt Architecture, 2012)
Figure 22: ‘Out of the Blue’ Passive House – Construction Stage. (MosArt Architecture, 2012)
Figure 23: Schock Novomur Insulated Bock – Construction Stage (Marlok, 2014)
Figure 24: Triple Glazed Section Unit (MosArt Architecture, 2012)
Figure 25:Window Components (MosArt Architecture, 2012)
Figure 26: Floor Components (MosArt Architecture, 2012)
Figure 27: Wood Pellet Stove in ‘Out of The Blue’ (O’Se, 2010)
Figure 28:Radiators used in ‘Out of the Blue (O’Se, 2010)’
Figure 29: Questionnaire Respondents (Total number = 31)
Figure 30: Experience of Respondents ( Total number = 31)
Figure 31: Question 1 – Online Questionnaire
Figure 32: Question 2 – Online Questionnaire
Figure 33: Question 3 – Online Questionnaire
Figure 34: Question 4 – Online Questionnaire
Figure 35: Question 5 – Online Questionnaire
Figure 36: Question 6 – Online Questionnaire
Figure 37: Question 7 – Online Questionnaire
Figure 38: Question 8 – Online Questionnaire
Figure 39: Question 9 – Online Questionnaire
Figure 40: Questions 10 & 11 – Online Questionnaire
Figure 41: Question 12 – Online Questionnaire
Figure 42: Question 13 – Online Questionnaire
Figure 43: Question 14 – Online Questionnaire
Figure 44: Question 16 – Online Questionnaire
Figure 45: ‘Out of the Blue’ Passive House – Ireland’s
Figure 46: ‘Out of the Blue’ Passive House – Thermal Mass
Figure 47: MHRV for ‘Out of the Blue Passive House
Figure 48: Aperture area Solar Panels
Figure 49: Triple glazed window being installed in Out of the Blue’ Passive House
Figure 50: Airtight window – ‘Out of the Blue’ Passive House
Table 1: : Potential for space heating energy and carbon dioxide savings. (SEAI, 2007, p. 8)
Table 2: Technical Definition of the Passive House Standard for Ireland. (SEAI, 2007)
Table 3: Material Suitable to meet PH Standard U-value of 0.13 W/ (m²K). (Passipedia, 2017)
Table 4: Breakdown of respondents opinions
Table 5: Question 14 – Online Survey
BER- Building Energy Rating
CEPHEUS- Cost Efficient Passive Houses as European Standard
CIF- Construction Industry Federation
CO2- Carbon Dioxide
CPHD- Certified Passive House Designer
DEAP- Dwelling Energy Assessment Procedure
EPC – Energy Performance Coefficient
DIT- Dublin Institute of Technology
EPBD- European Performance of Buildings Directive
H&S- Health & Safety
IPHT- Institute of Passive House Training
M&E- Mechanical & Electrical
MHRV- Mechanical Heat Recovery Ventilation
m 3 /h/m2 – meters cubed per hour per square meter
kWh/m2 /yr- Kilowatt hours per square meter of floor area per year
Pa- Pascal
PH- Passive House
PHA- Passive House Academy
PHI – Passivhaus Institute
PHPP – Passive House Planning Package
PEPH – Promotion of European Passive Houses
IPHA- International Passive House Association
SEI- Sustainable Energy Ireland
SEAI- Sustainable Energy Authority of Ireland
TGD- Technical Guidance Document
TGD L- Technical Guidance Document Part L (Irish Building Regulations)
UK- United Kingdom
USA- United States of America
UCD- University College Dublin
W/m2K – U-value (the rate at which heats flows through building fabric)
The Celtic Tiger is the name given to the unique but unexpected economic growth in Ireland from the mid 1990’s to 2007. The construction industry was a large driving force of the economic boom, many truths about long-term damage which can be done by uncontrolled economic growth are beginning to surface.
The enforcements of regulations during the Celtic Tiger was unnoticed and unheeded, this meant that new houses that were built did not perform well energetically with heat loss due to badly installed insulation and due to a lack of air tightness being achieved.
This not only has a negative effect on the thermal comfort of the house but also the cost of maintaining temperatures in the house.
This is added to the fact that there are already existing older houses, the majority of which would perform very badly in a Building Energy Rating (BER) test.
For the last number of years, the Passive House standard for building a house has been implemented greatly across many parts of Europe, it has been seen as a way to counter the rising fuel costs and to provide sustainable housing.
The planning that is required for such housing is vastly detailed with the main contributors to its effectiveness being passive solar gain, building orientation and building form.
Ireland also has an issue to when it comes to CO2 emissions, this was another key factor to why the new building regulations were introduced as it is currently the government’s intention that by 2020 legislation will have brought Ireland to the point where all new housing is zero-carbon low energy housing.
In 2007 a report of the Inter-Governmental Panel on Climate Change
(IPCC) shows that climate change is already a very serious global issue. Discusses how it will have a negative effect on the ecosystem, the economy and on living conditions are anticipated to be on a massive scale.
Passive House also plays a key role in reducing the impact of global warming, according to Sustainable Energy Ireland (SEAI) ‘’Ireland’s mild climate puts it in a favourable position to introduce Passive Houses to mainstream construction compared to the more severe climates prevalent in central Europe’’
The main scope of this dissertation is to investigate the passive house concept as a model for the sustainable construction of homes in Ireland and the benefits and limitations of applying the passive house standards to homes in Ireland.
This dissertation examines and investigates Passive House as a suitable building method for use in Ireland to provide a sustainable home.
There are a number of factors under consideration in this document. These are as follows:
In Ireland
achieve 60% aggregate improvements over the 2007 standards in both the energy performance and associated carbon emissions of new dwellings from 1 December 2011. Given that residential energy represents over a quarter of final energy use, the framework underpinning these targets has massive potential for Ireland.
The main scope of this dissertation is to investigate the passive house concept as a model for the sustainable construction of homes in Ireland.
This chapter provides an introduction to the document, outlines the aims and objectives of the document. It also provides an overview of the contents of the dissertation.
This chapter examines already published information on the topic. This includes a comprehensive review of the Passive house concept and a brief review of the evolution of the Passive house standards. This chapter also provides a detailed investigation of the exact criteria required to meet passive house standards such as quality control, insulation, thermal bridging, air tightness, ventilation, energy efficiency, thermal comfort.
This chapter provides an explanation of the research methods that were used. This includes a review of primary and secondary data as well as qualitative and quantitative research methods.
This chapter will examine relevant case study and to look at the key aspects of it in relation to the Passive House concept.
This chapter analyses the data obtained from the structured online interviews of industry professionals. Industry professionals were surveyed to gain a measure of their knowledge and attitude towards sustainable construction and the use of Passive House as a means to meet the Technical Guidance Document (TGD) Part L of the Irish Building Regulations.
This chapter will present the findings of the data received and all the information obtained throughout the project. The data received is examined and summarised.
This chapter presents the conclusions and recommendations arising from the research.
2.0 LITERATURE REVIEW
This literature review seeks to examine and investigate the main elements associated with Passive Houses (PH).
The PH standard has been used in Ireland for a number but it is still relatively new and is very complex. This chapter will investigate the key concept and the history of Passive House and the criteria or standards required, this includes topics such as thermal quality control, insulation, thermal bridging, airtightness, windows and ventilation. Furthermore, discussions on the current 2011 Irish Building Regulations specifically Part L of the Regulations.
Passive House is a scientific tool which sets a standard to achieve exceptional comfortable and healthy living conditions. Waljen (Waltjen, 2009, p. 14) defines a Passive House (PH) as ‘a building in which thermal comfort is solely guaranteed by-reheating (or re-cooling) the volume of fresh air that is required for satisfactory air quality – without using circulation air’
The Passive House techniques works for both new and refurbished buildings of all types and sizes. The PH method has been tested throughout Europe, US, Canada and even in hot Asian climates with most seen as successful. The design technique first commenced in the central European climate with its cold and windy winters but through performance monitoring it’s been shown that PH is best suited to the milder climate of the British Isles. (SEAI, 2007)
The international ISO 7730 (ISO, 2005) describes PH as a building in which thermal comfort can be provided by post heating or cooling of the fresh air flow that is required for good indoor air quality.
A PH is a building in which a comfortable interior climate can be maintained without active heating and cooling systems according to (adamson 1987 and feist 1988). There is strong emphasis in this definition in regards to comfort and reheating of fresh uncontrolled air.
PH does not require the use of central heating system. Heat demand can be satisfied through a small heater that is integrated into the Mechanical Ventilation Heat Recovery (MVHR) system. The MVHR system is utilised to provide excellent air quality and highly efficient heat recovery.
In essence, a Passivhaus is “a building in which a comfortable interior climate can be maintained without active heating and cooling systems”(Fiest, 1988)
PH standard aims to achieve good comfort during winter and summer, without traditional space heating systems and without active cooling need to have not only good indoor air quality maintained by a mechanical ventilation system with highly efficient heat recovery but optimised insulation levels with minimal thermal bridges, very low air-leakage through the building, utilisation of passive solar and internal gains and good indoor air quality maintained by a mechanical ventilation system with highly efficient heat recovery. Renewable energy sources are used as much as possible to meet the resulting energy demand.
In the middle ages, especially in Island houses were built mainly from turf, this was because wood became scarce after forests of Europe had been mostly destroyed for firewood and agriculture. The turf walls were built very thick for stability and these walls were found to have good insulating qualities so very little heating was required.
These Icelandic homes were a very simple form of PH even although they didn’t have adequate windows or sufficient ventilation.
The first ever functioning PH was not a house but a polar ship. It was not seen then as PH but in hindsight the techniques used were like the PH standards used today. Fridtjof Nansen, the owner of the ship who was to travel to the North pole wanted to build a ship that would enable the crew of the sip to survive in temperatures up to minus 22°, he writes:
“The sides of the ship were lined with tarred felt, then came a space with cork padding, next a deal panelling, then a thick layer of felt, next air-tight linoleum, and last of all an inner panelling. The ceiling of the saloon and cabins . . . gave a total thickness of about 15 inches. …The skylight which was most exposed to the cold was protected by three panes of glass one within the other, and in various other ways. … The Fram is a comfortable abode. Whether the thermometer stands at 22° above zero or at 22° below it, we have no fire in the stove. The ventilation is excellent, especially since we rigged up the air sail, which sends a whole winter‘s cold in through the ventilator; yet in spite of this we sit here warm and comfortable, with only a lamp burning. I am thinking of having the stove removed altogether; it is only in the way “ (PASSIPEDIA, 1998)
Figure 1: The Research Ship “Fram” was a Passive House (PASSIPEDIA, 1998)
However the PH standard was born in 1988 by two men called Professor Bo Adamson of Lund University, Sweden, and Dr Wolfgang Feist of the Institute for Housing and the Environment. They were great believers in low energy buildings and the key role it could play in building design but relised that more development in key ideologies for low eneregy housing was required. In order to test the practical fesability of the PH concept a number of pilot PH were designed most noterability the Kranichstein PH in Darmstadt, Germany.
The first PH homes comprised of four terraced houses which became the first occupied multi family home to attain a heating energy consumption of 12kWh/(m2a) considering the standard home in 1990 achieved just 10% better. The energy monitering performance proved that the PH startegy was successful in relation to low energy consumption. The net energy consumption across the four homes (space heating + domestic hot water +electricity) showed that the buildings required very little heating (below 10 w/m2). Dr Feist in his thesis states how he was so happy with the the success of the PH and his objective of this development was to set a stage as a model of low energy homes that could be constructed at a resonable cost.
In 1996 an independent research organisation was founded, The Passive House Institute (PHI), to promote and control the Passive House standard and has played a crucial role in the development of the Passive House concept (Fiest, 1988) (Bere, 2013)
Building on the success of the pilot scheme a new programe was brought in to meet energy challenges called CEPHEUS. The Cost Efficient Passive House as European Standards (CEPHEUS) was a strategy which aimed to improve the energy efficiency of homes throughout Europe. The CEPHEUS project ran from 1998 to 2001 and involved the construction of 250 houses built to PH standard across five Europen countries, Germany, France, Austria, Sweeden and Switzerland. The in-use energy of these homes was monitered and the results showed that it had achieved its goals in a majority of the sub-projects. The avaeage heat demand found was 16.6 Wh/m2/yr. The extra cost of construction of the unit was seen to be less than 10% above above what the normal applicable requirements for that region was. The project also paid close attention to user comfort and it was recorded in the results which showed a high level of user acceptance to PH.
The CEPHEUS project is seen as a major influence in the promotion and growth of PH standard across Europen including Ireland where in 2007 Duncan Steward, from RTE television show About the House, took a visit to one of the CEPHEUS projects in Goteborg, Sweden. (Bere, 2013) (RTE TV)
In 1997 an agreenment called Kyoto Protocol came into effect with the propoosed effect of reducing the Co2 emmisions in Ireland by up to 13%. It is an agreement under which the industrialised countries will reduce their collective Co2 emissions of greenhouse gases.
Ireland together with 160 other countries committed to the Kyoto Protocol. It is a legal binding commitment to reduce the amount of greenhouse gases over an agreed period. Ireland had agreed to limit its emissions by 13% between 2008 -2012 and due to the recession that hit Ireland it helped Ireland to meet its Kyoto targets by the end of 2012. Irelands Kyoto target now is to reduce Co2 emmisions by 20% by 2020.
This was one of the main reasons why PH came into Ireland. The first time PH was introduced into Ireland was by Architect Tomas O’Leary in 2000. At this time Tomas attended the ‘’see the light conference’’ in Kerry where the PH concept was introduced into Ireland. The house was built in County Wicklow and the house was aptly named “Out of the Blue” as the sky provides a majority of the heat demand for the house. (Rose, 2015)
Today the PH has become a worldwide building strategy and a generic term to describe low energy buildings. As of 2014 there are estimated to be 40,000 buildings certifed to the PH standard and many more inspired by the PH model concept.
In Ireland there are around nine PH certified by PHI and approxamenely 50 projects so far which have been completed in Ireland both new builds and retrofits. (Rose, 2015) (Ebbs, 2012)
Figure 2: “Out of the blue” – Irelands first certified PH (ARCHITECTURE, 2007)
UCD Energy Group (2008) carried out a study to analysis the existing housing stock in Ireland and calculated figures for energy required for space heating and carbon emission savings which could be achieved if the PH Standard was implemented. The study found that houses which were built in 2002 using the 2002 building regulation standards consumed on average 9,722kWh/year delivered energy on space heating and as a result emitting 2,855 kgCO2/year into the atmosphere. The exact same dwelling built to PH Standard was found to be only 1.500kWh/year of delivered energy, emitting 176 kgCO2/year.
Based on an estimated average of 40,000 homes built per year over a 20-year period, potential energy and CO2 emissions saving rates were calculated. The results show that substantial savings are achieved by using the PH Standard in Ireland. (SEAI, 2007, p. 8)
Percentage (and number) of new dwellings built to Passive House Standard | Potential energy and CO2 emissions savings per year | Potential energy and CO2 emissions savings in 20 years |
1% (400) | 3.29 GWh | 0.691 TWh |
1.07 ktCO2 | 5.02 MtCO2 | |
5% (2,000) | 16.44 GWh | 3.453 TWh |
5.36 ktCO2 | 25.10 MtCO2 | |
20%(8,000) | 65.78 GWh | 13.813 TWh |
21.44 ktCO2 | 100.41 MtCO2 | |
50% (20,000) | 164.44 GWh | 34.533 TWh |
53.59 ktCO2 | 251.03 MtCO2 |
Table 1: : Potential for space heating energy and carbon dioxide savings. (SEAI, 2007, p. 8)
The impact of this research is shown in figure 3 below, which shows the yearly savings which could be made by implementing the PH Standard as Building Regulations in Ireland.
Figure 3: Potential energy and CO2 savings to be made by implementation of the Passivhaus standard as Irish Building Regulations (SEAI, 2007)
To be fully eligible and to have the status of PH certification, it must be received from the Passive House Institute in Darmstadt, Germany. Over the last number of years, a small number of Irish companies have become registered PH Institute partners and through this partnership can award genuine PH Institute certifications, subject to meeting the required criteria and PH standards.
In 1998 a computer software package called PHPP (Passive House Planning Package) was developed by the Passive House Institute (PHI). This package was developed to enable designers and builders to calculate the energy demand of a building and to ensure that the building meets the PH standards and the required design criteria. Since its inception in 1998 the PHPP program package has been developed on a continuous basis. There are currently several Irish companies using this programme including MosArt Architecture in Wexford, PH builders Vikings Hose in Dublin and Scandinavian Homes in Moycullen Galway.
In order for certification construction drawings must be provided, these drawings include all details with special emphasis on details at floor level, around doors and windows and at roof junctions as it is vital that thermal standards are withheld. Details of ventilation systems and heat recovery systems must be included in submission. Technical specifications, material data sheets and a certificate of air tightness testing must also be included in submission.
Before the application for certification it is necessary that the Project Supervisor sign off on the building verifying that all details and drawing submitted have been kept and are correct and that the building was built accordingly. Photographs of the finished building should also be provided when submitting to the certifying body. (Young, 2008)
The following table shows the principles that must be met for a dwelling to be classified as a Passive House.
Measure/Solution | Passive House Standard for the Prototype House in the Irish Climate |
|
|
Insulation Walls | U < 0.175 W/m2 K |
Insulation Roof | U < 0.15 W/m2 K |
Insulation Floor | U < 0.15 W/m2 K |
Windows, Frames, Doors | U < 0.8 W/m2 K |
Window Glazing | U < 0.8 W/m2 K |
Thermal Bridges | Linear heat Coefficient Ψ < 0.01 W/mK |
Structural Air Tightness | n50 < 0.6/ air changes per hour |
|
|
Ventilation counter flow air to air heat exchanger. | Heat Recovery Efficiency > 75% |
Minimal Space Heating | Post heating ventilation air/ Low temperature |
You Want The Best Grades and That’s What We Deliver
Our top essay writers are handpicked for their degree qualification, talent and freelance know-how. Each one brings deep expertise in their chosen subjects and a solid track record in academic writing.
We offer the lowest possible pricing for each research paper while still providing the best writers;no compromise on quality. Our costs are fair and reasonable to college students compared to other custom writing services.
You’ll never get a paper from us with plagiarism or that robotic AI feel. We carefully research, write, cite and check every final draft before sending it your way.